| Place of Origin: | CHINA |
|---|---|
| Brand Name: | HB |
| Certification: | ROHS |
| Model Number: | HB553759 1350mAh |
| Minimum Order Quantity: | Contact sales to get |
| Price: | Contact sales to get |
| Packaging Details: | Contact sales to get |
| Delivery Time: | Contact sales to get |
| Payment Terms: | T/T |
| Supply Ability: | Contact sales to get |
| NominalVoltage: | 3.7V | NominalCapacity: | 1350mAh |
|---|---|---|---|
| Warranty: | 1Year | CycleLife: | 500Times |
| StandardDischargeCurrent: | 0.2C | 1 | 1 | StandardChargeCurrent: | 0.2C |
| HighLight: | rechargeablelithiumbatteries,lithiumpolymerbattery |
553759 Li Polymer Battery 1350mAh soft pack Infrared thermometer battery 3.7V
1. Technical Parameters
| Item | Specification | Note |
| Nominal Capacity | 1350mAh | 0.2C discharge |
| Min. Capacity | 1250 mAh | 0.2C discharge |
| Cell Weight | ≈21g | |
| Cell Initial Impedance | ≤ 80mΩ | 3.7V AC 1KHz measured |
| Normal Voltage | 3.7 V | |
| Initial Voltage | ≥3.8V | |
| Limited Charge Voltage | 4.2 V | Voltage of CC charge to CV charge |
|
|
|
|
| Cut-off Voltage | 2.75 V | Load Voltage when discharge ended |
| Standard Charging Current | 270mA (0.2C) | |
| Standard Charging Time | 6~7 hours | CC charge to 4.2 V, then CV charge till |
| current declines to less than 0.01C | ||
| Rapid Charging Current | 1350 mA (0.5C) | |
| 0.01C | ||
| Rapid Charging Time | 约1.5hours | |
| Standard Discharging Current | 270mA (0.2C) |
|
| Max. Discharging Current | 1350mA (1C) | |
| Operating Temperature Range |
Charging:0 ~ 45℃ |
|
| Operating humidity Range | ≤ 90%RH | |
| Item | Criterion | Test Method |
|
0.2C dischargring capacity |
Discharging capacity is not less than normal capacity |
After Standard Charging,rest 5 minutes,then 0.2C discharge to cut-off voltage |
|
1.0C dischargring capacity |
Discharging capacity is not less than 90% of normal capacity |
After Standard Charging,rest 5 minutes,then 1.0C discharge to cut-off voltage |
| Cycle life |
The cycle times is not less than 300 |
Charge:0.5C CC-CV charge to 4.2 V, then current declines to 0.02C |
| Self-discharge |
Discharging capacity is not less than 85% of initial capacity |
After Standard Charging,rest the cell for 28 days in the condition of 20±5℃, then 0.2C discharge to cut- off voltage, and record the capacity. |